내용 자세히 확인하기(설명서,데이터시트 등)

Fluke 87V/E2 산업 전기 기사용 콤보 키트

제품 개요

이 새로운 키트는 Fluke 87V를 기반으로 하며, 산업 문제를 훨씬 생산적으로 해결할 수 있는 특수 액세서리가 포함되어 있습니다. 모든 액세서리를 개별적으로 구입할 때보다 15% 절약됩니다.


구성:

  • 87V 멀티미터
  • TL224 실리콘 테스트 리드
  • AC220 긴 앨리게이터 클립
  • TP238 테스트 프로브
  • TPAK ToolPak™ 자석 미터 걸이 키트
  • 80BK 온도 프로브
  • C35 경량 소프트 액세서리 케이스
  • 9V 배터리(장착됨)

주요 기능

Electrical safety

All inputs are protected to the 2nd edition of ANSI/ISA S82.01 and EN61010-1 CAT IV 600 V and CAT III, 1000 V. They can withstand impulses in excess of 8.000 V and reduce risks related to surges and spikes.

Correctly measure pulse-width modulated motor drive signals

Until now, there hasn't been a multimeter able to accurately measure adjustable speed drives. But the Fluke 87V is designed specifically to handle these complex signals. Think of the potential productivity you'll gain by taking the guesswork out of drive system troubleshooting. Measurements are correct each and every time.

Specifications
Voltage DCMaximum Voltage1000 V
Accuracy±(0.05% + 1)
Maximum Resolution10 µV
Voltage ACMaximum Voltage1000 V
Accuracy±(0.7% + 2) True RMS
AC Bandwidth20 kHz with low pass filter; 3 db @ 1 kHz
Maximum Resolution0.1 mV
Current DCMaximum Amps10 A (20 A for 30 seconds maximum)
Amps Accuracy±(0.2% + 2)
Maximum Resolution0.01 µA
Current ACMaximum Amps10 A (20 A for 30 seconds maximum)
Amps Accuracy±(1.0% + 2) True RMS
Maximum Resolution0.1 µA
ResistanceMaximum Resistance50 MΩ
Accuracy±(0.2% + 1)
Maximum Resolution0.1Ω
CapacitanceMaximum Capacitance9,999 µF
Accuracy±(1% + 2)
Maximum Resolution0.01 nF
FrequencyMaximum Frequency200 kHz
Accuracy±(0.005% + 1)
Maximum Resolution0.01 Hz
Duty CycleMaximum Duty Cycle99.9%
Accuracy±(0.2% per khz +0.1%)
Maximum Resolution0.1%
Temperature Measurement-200.0°C - 1090°C
-328.0°F - 1994.0°F
excluding probe
80 BK Temperature Probe-40.0°C - 260°C
-40.0°F - 500°F, 2.2°C or 2% whichever is greater
ConductanceMaximum Conductance60.00 nS
Accuracy±(1.0% + 10)
Maximum Resolution0.01 nS
DiodeRange3 V
Resolution1 mV
Accuracy±(2% + 1)
Duty Cycle RangeAccuracyWithin ±(02% per kHz +0.1%)
Environmental Specifications
Operating Temperature-20°C to +55°C
Storage Temperature-40°C to +60°C
Humidity (Without Condensation)0% - 90% (0°C - 35°C)
0% - 70% (35°C - 55°C)
Operating Altitude2000 m
Safety Specifications
Overvoltage categoryEN 61010-1 to 1000 V CAT III, 600V CAT IV
Agency ApprovalsUL, CSA, TÜV, VDE listed
Mechanical and General Specifications
Size201 x 98 x 52 mm (with holster)
Weight355 g
624 g - with holster
DisplayDigital6000 counts updates 4/sec.
19,999 counts in high-resolution mode
Analog32 segments, updates 40/sec.
Frequency19,999 counts, updates 3/sec at > 10 Hz
WarrantyLifetime
Battery LifeAlkaline~400 hours typical, without backlight
Shock1 Meter drop per IEC 61010-1:2001
VibrationPer MIL-PRF-28800 for a Class 2 instrument